Owner’s Manual Polaris Power P3200iEBT Generator |
The Owner's Manual for this vehicle contains warnings, instructions and other information you must read and fully understand before safely riding or performing maintenance on this vehicle. Always follow the warnings and instructions in Owner's Manual.
Click the link above for the Table Of Contents, or download a full PDF of the Owner Manual in the Owner Support area of Polaris.com.
Polaris Power® P3200iEBT
Trademarks
POLARIS® and POLARIS POWER® are trademarks of POLARIS Industries Inc. Unless noted, trademarks are the property of Polaris Industries Inc.
Google Play® and Android® are registered trademarks of Google LLC. Apple® is a registered trademark of Apple Inc. BatteryMINDer® is a registered trademark of VDC Electronics Inc. Bluetooth® is a registered trademark of Bluetooth Sig, Inc.
Copyright Information
Copyright 2024 Polaris Industries Inc. All information contained within this publication is based on the latest product information at the time of publication. Due to constant improvements in the design and quality of production components, some minor discrepancies may result between the actual vehicle and the information presented in this publication. Depictions and/or procedures in this publication are intended for reference use only. No liability can be accepted for omissions or inaccuracies. Any reprinting or reuse of the depictions and/or procedures contained within, whether whole or in part, is expressly prohibited.
The original instructions for this vehicle are in English. Other languages are provided as translations of the original instructions.
Printed in China
Printed in China
i Welcome
Designed in our labs, put to the test in yours.
Power for everything, for everyone. We've designed Polaris Power® with that simple principle in mind. From long weekend camping trips and tailgating to construction sites and power while you wait out the storm, we've got you covered.
Our line of generators are built for it all. No detail too small, no spec overlooked. We've redefined the definition of limits, so you can keep redefining yours.
-
P2000i Inverter Generator
-
P3200iEBT Inverter Generator
-
P5500 Open Frame Generator
-
P6500 Open Frame Generator
Your owner’s manual contains instructions for minor maintenance, but information about major repairs is outlined in the POLARIS Service Manual and can be performed by a POLARIS Dealer.
Your POLARIS dealer knows your generator best and is interested in your total satisfaction. Your POLARIS dealership can perform all of your service needs during, and after, the warranty period.
Chapter 1: Introduction
1.1.1: Overview
For a safe and enjoyable operation of your new generator, please read the entirety of this owner’s manual. If you should need additional assistance with generator operation or maintenance, please see your POLARIS dealer or other certified service technician.
After reading this manual in its entirety, store in a convenient location for future reference.
Intended Use
The Polaris Power® Generator is intended to supply power. Such items include, but are not limited to:
-
Furnace fans
-
Sump pumps
-
Dishwashers
-
Hotplates / stoves
-
Washing machines
-
Garage door openers
-
Water heaters
-
Refrigerators
-
Campers / RVs
-
Circular saws
Items that use more than the recommended amount of combined power consumption should not be connected to this generator.
1.1.2: Safety Symbols and Signal Words
The following signal words and symbols appear throughout this manual and on your generator. Your safety is involved when these words and symbols are used. Become familiar with their meanings before reading the manual.
DANGER indicates a hazardous situation which, if not avoided, WILL result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided, COULD result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, COULD result in minor to moderate injury.
NOTICE provides key information by clarifying instructions.
IMPORTANT provides key reminders during disassembly, assembly, and inspection of components.
The Prohibition Safety Sign indicates an action NOT to take in order to avoid a hazard.
The Mandatory Action Sign indicates an action that NEEDS to be taken to avoid a hazard.
1.1.3: Generator Identification Numbers
The generator serial number 1 and engine serial number 2 can be found stamped inside the maintenance cover beside the air box.
Record your generator’s serial numbers and purchase date in the spaces provided.
Model Number | P3200iEBT |
Generator Serial Number | |
Engine Serial Number | |
Purchase Date |
Chapter 2: Safety
2.2.1: Safety Warnings
Understand and follow all inspection and maintenance procedures outlined in this manual. Following these procedures is essential for the generator to remain in safe operating condition.
If the generator is not in use for an extended period of time, turn the ignition switch and fuel valve switch to the OFF position.
2.2.1.1: Operator Safety
Please take the following precautions, which are essential for proper and safe operation:
-
Read and understand all of the safety and operating information in this manual and on all warning and instruction labels before using the generator. Use the generator only as described in this manual and on the product.
-
Know how to stop the generator quickly in case of emergency, see page 19 for information on stopping the unit quickly.
-
Keep children, pets, and bystanders at a safe distance from the generator.
-
Review and understand the use of all generator controls, output receptacles, and connections.
-
Be sure that anyone who operates the generator receives proper instruction and reads this manual completely. Do not let children operate the generator.
-
Use the generator only for intended purposes.
-
Turn off the generator immediately if the unit begins to operate abnormally. After the generator has cooled, disconnect the generator and take to your authorized Polaris dealer.
-
While operating the generator, if you experience a headache, fatigue, nausea / vomiting, confusion, or seizures, immediately get to fresh air. Do not delay and do not attempt to shut down the unit.
2.2.1.2: Operating Without Instruction
The operator must understand how to
operate the generator safely in proper conditions and environments.
All operators must read and understand the
owner's manual and all warning and instruction labels before operating
the generator.
2.2.1.3: Failure to Inspect Before Operating
-
Failure to inspect and verify that the generator is in safe operating condition before operating increases the risk of an accident resulting in severe injury or death.
-
Always perform the pre-operation inspection before each use of your generator to make sure it's in safe operating condition.
-
Always follow the inspection and maintenance procedures and schedules described in this owner’s manual.
2.2.1.4: Using Alcohol or Drugs
Never consume alcohol or drugs before or while operating this generator.
Operating this generator after consuming alcohol or drugs could adversely affect operator judgment.
2.2.1.5: Carbon Monoxide Safety
ALWAYS operate generator according to all warning and instruction labels and this manual.
-
This portable generator runs on gasoline. The generator exhaust vapor contains carbon monoxide (CO).
-
Carbon monoxide is odorless. You cannot smell it.
-
Carbon monoxide is colorless. You cannot see it.
-
The generator is for outdoor use only. Never run the generator in an enclosed area. Exhaust contains poisonous carbon monoxide vapor that can cause loss of consciousness or death. Operate the generator in an open, and well ventilated area.
-
Do not use the generator indoors in garages, basements, crawl spaces, sheds, portable buildings, or similar areas even if doors and windows are open or if ventilating fans are used to circulate air.
-
Do not use the generator near windows, doors, vents or any other building openings even if they are closed. Poor seals on a door, as one example, could still permit high levels of carbon monoxide to infiltrate the living area of a home.
-
Be sure to install approved carbon monoxide detectors in your home that have battery back-up systems that will continue to detect the presence of carbon monoxide during electric-power outages. Test these devices and replace batteries as recommended by their respective manufacturers.
2.2.1.6: Electrical Safety
-
The generator produces enough electric power to cause serious shock or electrocution if misused.
-
Always connect the generator to a suitable ground circuit.
-
When servicing the generator, disconnect the spark plug wire and place it where it cannot contact the plug. Turn the engine switch to the OFF position.
-
Do not check for a spark with the plug removed. Use only approved spark plug testers.
-
Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in severe shock or electrocution. Keep the generator dry and away from all sources of moisture.
-
If the generator is stored outdoors, unprotected from the weather, check all electrical components on the control panel before each use. Moisture or ice can cause a malfunction or short circuit in electrical components that could result in electrocution.
-
Do not connect the generator to a building’s electrical system unless an isolation switch has been installed that meets applicable electrical codes and regulations.
-
To avoid overloading the generator, ensure load is kept within the rated power range stated on the generator. Overloading will damage the unit and / or shorten its operating lifespan.
2.2.1.6.1: Extension Cord Use
Read the manufacturer starting and running wattage details and operating instructions for the device(s) and appliance(s) that will be used. Often this information can be found in the owner's manual or on specification decals on the device or appliance.
Choosing A Proper Extension Cord
Polaris recommends using only U.L. (Underwriters Laboratories, Inc.) approved extension cords labeled with the use, size, and wattage rating.
Only use heavy-duty extension cords with a three-prong (grounded) plug for your safety.
Decide on what length extension cord is required as cord length determines the extension cord gauge. Remember, as the cord gets longer, the current capacity of the cord decreases.
Never use an extension cord outdoors that is designated as “indoor use only”.
Extension Cord Safety
Store all extension
cords indoors when not in use. Outdoor conditions can deteriorate
a cord over time.
Before plugging an
extension cord or power cord into the generator, check the cord for
signs of damage.
2.2.1.7: Fire Safety
Refuel in a well-ventilated area with the engine OFF.
-
Keep the generator at least 3 feet (1 m) away from buildings, other equipment, and combustible materials during operation.
-
Do not enclose the generator in any structure.
-
Keep children and pets away from generator.
-
Exhaust system components are very hot during and after use. Hot components can cause burns and fire. Do not touch the hot exhaust system components. Always keep combustible materials away from the exhaust system.
-
Ensure that any spilled fuel is properly wiped up prior to using the generator as fuel vapors are flammable.
2.2.1.8: Exposure to Exhaust
Exhaust fumes from your generator are poisonous and can cause loss of consciousness or death in a short time. Never start the generator or let it run in an enclosed area. Only operate this generator while outdoors.
2.2.1.9: Hot Exhaust Systems
Exhaust system components are very hot during and after use of the machine. Hot components can cause burns and fire. Do not touch hot exhaust system components. Always keep combustible materials away from the exhaust system.
Use caution when operating near tall grass, especially dry grass. Always inspect the exterior of the generator and areas near the exhaust system before and after use. Promptly remove any grass, debris, or foreign matter clinging to the generator. Pay particular attention to the exhaust system area.
2.2.1.10: Running Generators in Parallel
Only connect in parallel with a Polaris Power P3200iE, P3200iEBT, P2500iEBT, or P2000i generator using an approved parallel cable (sold separately). Attempting to connect other brands or models will void your warranty and could cause severe injury.
2.2.1.11: Equipment Modifications
Your POLARIS generator is designed to provide safe operation when used as directed. Modifications to your generator may negatively impact generator stability. Failure of critical machine components may result from operation with any modifications, especially those that increase power.
Do not install any non-POLARIS-approved accessory or modify the generator for the purpose of increasing power output. Any modifications or installation of non-POLARIS-approved accessories could create a substantial safety hazard and increase the risk of bodily injury.
Modifying the generator by adding or removing any parts, components, or any modifications not approved by Polaris may void the warranty. Such modifications may make the generator unsafe to operate and could result in severe injury to operators and bystanders, as well as damage to the generator. Some modifications may not be legal in your area. If in doubt, contact your authorized POLARIS dealer.
2.2.1.12: Handling Gasoline
-
If the generator has been in operation, allow engine to cool completely before refueling.
-
Always store gasoline in an approved container.
-
Always refuel outdoors or in a well-ventilated area away from any combustible materials.
-
Do not smoke or allow open flames or sparks in or near the area where refueling is performed or where gasoline is stored.
-
Never permit children to handle gasoline.
-
Never refuel around bystanders, pets, and flammable objects.
-
Loosen the fuel cap slowly to relieve pressure in the tank.
-
Take care not to overfull or spill any fuel on the generator or muffler when refueling.
-
If spills occur, wipe up with a clean, dry cloth and let generator sit for 10 minutes in a well-ventilated area to allow fumes to evaporate completely.
-
If gasoline spills on skin or clothing, immediately wash it off with soap and water and change clothing.
-
Do not use the generator if you observe leaking gasoline. Have the generator serviced immediately and before using it again.
-
When operating or transporting the generator, be sure it is kept upright. If it tilts, fuel may leak. Be sure the fuel tank cap is tightened when transporting the generator.
-
Do not refuel using gas station pumps.
-
Remove fuel from the generator before transporting in a vehicle.
Do not swallow gasoline, inhale gasoline vapors, or spill gasoline. If you swallow gasoline, inhale more than a few breaths of gasoline vapor, or splash gasoline in your eyes, see a physician immediately. If gasoline spills on skin or clothing, immediately wash it off with soap and water and change clothing.
2.2.2: Operation Rules
-
Perform all Pre-Operation Inspection activities as shown on Pre-Operation Inspection of this manual. Inspect and tighten all parts before each use. Ensure the generator does not have any damaged, loose, or missing parts before use. All defects should be corrected before use. Do not operate the generator if it has been dropped or damaged until all defective parts have been repaired.
-
Do not place any flammable materials near the generator.
-
Never start the generator or let it run in an enclosed area. Exhaust vapors are poisonous and can cause loss of consciousness or death in a short time. Keep the generator away from buildings and other equipment during operation.
-
Do not operate the generator in exposed locations where it will be subjected to wet conditions.
-
Do not touch the generator with wet hands, as this may cause severe electric shocks.
-
Do not pour water directly over the generator or wash it.
-
Do not use or store the generator in the rain or snow.
-
Do not cover the generator when in use.
-
Always operate the generator on a firm, flat, and level surface, as the generator will vibrate on an irregular surface.
-
If the generator is tilted, fuel may spill or the generator may tip over, causing a hazardous situation. Lock the wheels before using.
-
Do not connect the generator to another power supply source.
-
The engine becomes extremely hot during and immediately after it has been in use. Be careful not to touch any parts of the hot engine, especially the muffler or muffler cover, or serious burns may result.
-
Do not connect external equipment to the generator before starting the engine.
-
Do not use for life support, or life sustaining systems.
2.2.3: Noise Level
The following noise chart lists average decibel levels for everyday sounds and appliances.
Danger Level | Sound | Decibel Level | Permissible Exposure Time | Safety Recommendation |
---|---|---|---|---|
Painful Impulse Noise | Fireworks (3 ft) / Shotgun Blast | 150 dBP | Not safe for any period of time. | Avoid exposure. Not safe for any period of time. |
Firearms | 140 dBP | Not safe for any period of time. | ||
Painful Steady Noise | Jackhammer | 130 dB(A) | Not safe for any period of time. | |
Jet Plane Takeoff / Siren | 120 dB(A) | Not safe for any period of time. | ||
Extremely Loud | MP3 Player Max Output / Rock Concert | 112 dB(A) | ~ 1 minute | Wear earplugs or earmuffs. |
Leaf Blower / Snow Blower | 106 dB(A) | > 4 minutes | ||
Hair Dryer / Blender | 94 dB(A) | 1 hour | ||
Very Loud | Passing motorcycle / Gas Lawn Mower | 91 dB(A) | 2 hours | |
Loud | Busy Traffic / Vacuum Cleaner | 85 dB(A) | 8 hours | No protection required. |
Moderate | Generator / Group Conversation | 70 dB(A) | Unlimited | |
Dishwasher / Clothes Dryer | 60 dB(A) | Unlimited | ||
Moderate Rainfall | 50 dB(A) | Unlimited | ||
Raindrop / Quiet Room | 40 dB(A) | Unlimited | ||
Faint | Whispering | 30 dB(A) | Unlimited |
2.2.3.1: Hearing Protection
Earmuffs are worn over the ears. They must completely surround the ear and fit snugly to reduce sound. Quality earmuffs, worn properly, can block up to 30 decibels of noise.
Earplugs are inserted into the ear to completely block the ear canal. Quality earplugs can reduce noise by up to 30 decibels.
2.2.4: Safety Labels and Locations
Warning labels have been placed on the generator for your protection. Read and follow the instructions on each label carefully. If any of the labels shown in this manual differ from the labels on your generator, always read and follow the instructions of the labels on the generator.
If an informational or graphic label becomes illegible or comes off, contact your POLARIS dealer to purchase a replacement. Replacement safety labels are provided by POLARIS at no charge. The part number is printed on the label.
1 General Warning |
3 Hot Exhaust Caution |
2 Carbon Monoxide Danger |
2.2.4.1: General Warning
The general warning is located on the top side of the generator near the fuel volume indicator.
Improper generator use can result in SEVERE INJURY or DEATH. Read the owner’s manual. Follow all instructions and warnings.
-
Gasoline is flammable and explosive. Severe burns can result.
-
ALWAYS stop the engine and let cool down before refueling.
-
ALWAYS check for fuel leaks and wipe up any spills.
-
ALWAYS turn the fuel to OFF when not in use.
-
NEVER handle gasoline indoors. NEVER overfill the fuel tank.
-
Generator exhaust contains poisonous Carbon Monoxide (CO) vapors.
-
ALWAYS operate in a well-ventilated area.
-
NEVER operate in a home, garage, enclosed area or near windows, doors, or people.
-
NEVER operate near flammable objects.
-
Electrocution can result from using generator in rain, snow, near water, with wet hands, or with improper connections.
-
ALWAYS keep generator and surrounding area dry.
-
NEVER connect generator to any building without electrical-isolation protection that meets applicable codes and regulations.
2.2.4.2: Carbon Monoxide Warning
The carbon monoxide warning label is located on the top side of the generator near the fuel level indicator.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
-
NEVER use inside a home or garage. EVEN IF doors and windows are open.
-
Only use OUTSIDE and far away from windows, doors, and vents.
2.2.4.3: Hot Exhaust Caution
The hot exhaust caution is located on the top side of the gas tank near the fuel volume indicator.
Contacting a hot exhaust system can cause serious burns. Do not touch if generator is or has been running.
Chapter 3: Features and Controls
3.3.1: Overview
Component | Description |
---|---|
1 Fuel Gauge |
Provides indication of fuel level. |
2 Control Panel |
Contains the switches, buttons, indicator panel, and receptacles for proper operation of the generator. |
3 Air Intake |
Provides air to cool the engine. |
4 Fuel Tank Cap |
Provides access to the fuel tank. |
5 Starter Grip |
Causes the recoil starter to crank the engine when pulled. |
6 Engine Oil Service Door |
Provides access to oil tank and dipstick. |
7 Folding Handle |
Allows for easier carrying and transport. |
8 Rear Handle |
Used combination with wheels to pull generator across flat surface. |
9 Air Exhaust |
Dispels exhaust air from cooling the engine. |
10 Muffler |
Reduces noise and emissions from engine combustion. |
11 Maintenance Cover |
Provides access to inner components for routine maintenance and repair. |
12 Wheels |
Used in combination with folding handle to roll generator across flat surface. |
3.3.2: Control Panel
Switches and Buttons
-
1 Engine Switch
-
2 Choke Lever (if equipped)
-
3 SMART Throttle Switch
-
4 Fuel Valve Switch
-
5 Parallel Socket
-
6 Overload Reset Button
-
7 Indicator Panel
Receptacles
8 Circuit Breakers |
11 USB Receptacles |
9 Ground Terminal |
12 120V AC Twist Lock Receptacle |
10 AC Receptacles |
3.3.2.1: Ignition Switch
The ignition switch must be in the RUN position for the generator to operate. Press the switch to the ON position to start the engine. The switch will automatically default to the RUN position upon release.
-
1 ON
-
2 RUN
-
3 OFF
3.3.2.2: Fuel Valve Switch
The fuel valve switch controls the fuel valve. When the engine is well-cooled and not in use, the fuel valve must be placed in the OFF position to reduce the possibility of fuel leakage.
The switch must be in the ON position to allow the engine to operate.
1 ON: opens the fuel valve.
2 OFF: closes the fuel valve.
3.3.2.3: SMART Throttle Switch
Press SMART throttle switch to ON position to automatically reduces engine speed when loads are shut off or disconnected. The engine will return to the proper speed when appliances are in use or reconnected.
Press the SMART throttle switch to the OFF position to reduce voltage changes when high electrical loads are simultaneously connected or when using the DC output.
3.3.2.4: Overload Reset Button
The overload reset button 1 is used in the case of sudden engine shutdown resulting from prolonged engine overload. Should the generator overload, AC power will be cut off but the engine will stay running. Correct the overload condition and then press the overload reset switch on the front panel. AC power will be restored immediately.
In the case of engine overload:
-
Disconnect all electrical appliances.
-
Hold reset button for 1 second to reset the engine.
-
If overload indicator light has turned off and output light has re-illuminated, reconnect electrical appliances.
-
If overload indicator light is still illuminated, set power switch to OFF and check generator.
3.3.2.5: Starter Recoil Grip
The recoil starter 1 is used as a secondary engine starter if the battery does not contain adequate charge to operate the starter motor.
3.3.2.6: Ground Terminal
-
The portable generator stator winding is isolated from the frame and from the AC receptacle ground pin; and
-
Electrical devices that require a connection between one conductor pin and the grounded receptacle pin may not function properly.
The ground terminal connects to the frame of the generator, metal parts that do not conduct current, and ground terminals of each receptacle.
3.3.2.7: AC Receptacles
The AC receptacles provide two connections for properly rated AC appliances.
3.3.2.8: Circuit Breakers
The circuit breakers automatically switch OFF if a short circuit or significant overload occurs to one or more of the receptacles.
-
1 AC Circuit Breakers
To reset the circuit protector, push button in to ON position.
3.3.2.9: 120V AC Twist Lock Receptacle
120V AC receptacle 1 provides
connection for properly rated, 120V AC appliances.
120V / 30 Amp
3.3.2.10: Indicator Panel
-
1 Low Oil Indicator
-
2 Overload Indicator
-
3 Load Stability Indicator
-
4 Mode Button
Indicator Lamps
Indicator Light | Description | |
---|---|---|
|
Fuel Level |
Indicates how much fuel remains in the generator. |
|
No Inverter Output |
Illuminates when no output is detected. |
|
Engine Temperature |
Illuminates if engine is over-temperature. |
|
Short Circuit Indicator |
Illuminates when a short circuit event has occurred. |
|
Connection Disruption |
No connection detected between inverter and indicator panel. |
|
Overload Indicator |
Illuminates when engine is overloaded. See Overload Reset Button for overload reset instructions. |
|
Output Level |
Indicates the level of power output being generated by the engine. |
|
Total Run Time |
Displays generator run time.
|
|
AC Wattage |
Displays current available wattage. |
|
AC Voltage |
Displays current available voltage. <110 / >130 volts |
|
Engine RPM |
Displays actual engine RPM. |
|
Service Required |
Illuminates when a service interval is reached. |
3.3.2.11: Parallel Socket
Two Polaris parallel-ready generators can be connected together to increase the total power available to a load, using the parallel socket 1.
The system seamlessly matches frequency
and automatically distributes the load to each generator evenly so
neither is overloaded.
Contact your
dealer to purchase a POLARIS parallel kit.
3.3.2.12: USB Ports
This generator is equipped with two
USB ports 1. A total of 3.1A data transfer speed is available
at 5 volts.
Each single port can draw
the full 3.1A or will be distributed as needed.
3.3.2.13: Choke Lever (if equipped)
Pulling the choke lever 1 provides proper fuel-starting mixture when the engine is cold. When attempting to start a cold engine, pull the choke lever outward to close. Slowly return the choke to the open position as the engine warms.
Chapter 4: Assembly
4.4.1: Importance of Proper Assembly
Proper assembly is essential to operator safety and the reliability of your generator. Errors and oversight made during unit assembly or service could result in faulty operation, damage to the machine, or operator injury.
4.4.2: Unboxing
-
Remove generator and loose parts from the box.
-
Compare loose parts to the inventory list below.
NOTICEContact your dealer if any of the loose parts listed below are not included with your generator.
Description | Quantity |
---|---|
Owner’s manual |
1 |
Tool Kit |
1 |
Warranty registration form |
1 |
Chapter 5: First Use Instructions
5.5.1: Adding Engine Oil
Polaris 5W-30 Generator Oil
19.6 floz (0.58 l)
-
Place generator on flat, level surface. Remove the maintenance cover.
-
Remove the oil filler cap / dipstick.
-
Fill the engine crankcase with the specified amount.
-
Insert the dipstick into the filler neck, without screwing it in.
-
Remove the dipstick and verify that the oil level is at the upper limit. Add additional oil and inspect the level as needed until the upper limit has been reached.
-
Re-install the dipstick. Use a clean shop rag to clean any spilled oil.
-
Re-install the maintenance cover.
5.5.2: Fuel
5.5.2.1: Fuel Recommendation
Polaris recommends the use of 87 octane fuel or higher.
- Never use stale or contaminated gasoline or an oil /gasoline mixture. Avoid getting dirt or water in the fuel tank.
-
Do not spill fuel when filling the fuel tank. Damage caused by spilled fuel is not covered under warranty. Spilled fuel is a fire hazard, causes environmental damage, and can damage paint and plastic. Wipe up spills immediately. Do not fill above bottom of strainer.
-
Refuel in a well ventilated area before starting the engine. If the engine has been running, allow it to cool.
-
Never refuel the engine inside a building where vapors may reach flames or sparks. Keep fuel vapors away from electrical appliances.
Do not use gasoline containing methanol. Damage due to ethanol or methanol is not covered under warranty.
-
Operating the generator with an obstructed fuel system will result in serious engine damage. Perform maintenance as recommended.
-
Thoroughly read “Safety” section and all safety information when handling fuel.
-
In order to insure the optimum output and the maximum service life of the generator, the generator should run at a 50% load for the first 20 hours.
5.5.2.2: Adding Fuel
To safely add fuel to the gas tank, perform the following steps.
-
Ensure fuel valve switch is OFF.
-
Remove the fuel tank cap 1.
-
Fill carefully to avoid spilling fuel on the fuel tank strainer. Do not overfill the fuel tank (there should be no fuel above the upper limit mark).
WARNINGDo not overfill. Fuel overflow may spill onto a hot engine and result in fire or explosion. -
Tighten fuel tank cap securely.
-
Position fuel switch to OFF for storage or ON to operate the generator.
-
Move generator away from fueling source and site before starting engine.
5.5.3: Pre-Operation Inspection
Item | Remarks | Page |
---|---|---|
Engine Oil | Check and add oil, as needed. | See Adding Engine Oil and Oil Change. |
Fuel Level | Check the fuel level and refuel, as needed. | See Refueling. |
Exhaust System | Inspect the exhaust system for leakage. Tighten or replace gasket, as needed. | See Spark Arrester. |
Carburetor | Inspect choke knob operation (if equipped). | See Choke Lever (if equipped). |
Level Ground | Ensure the generator is resting on a level surface to prevent spills or tip-over. | – |
Grass and Leaves | Remove grass, leaves, and other flammable material or debris, especially near the HOT exhaust system. | See Hot Exhaust Systems. |
Chapter 6: Polaris Mobile App
6.6.1: Device Operating Requirements
Phone functionality is dependent on the capabilities of your cell phone.
6.6.2: Overview
This generator utilizes the Polaris app for digital gauge readings and remote start features. For optimum use of your generator, follow the directions below to download the Polaris app, available for both Apple® and Android® smartphones.
Scan the QR Code® on the side of your generator to download the Polaris app from the Apple® or Google Play® store and create or log into you Polaris account. If the Polaris app is already installed on your smartphone, scanning the QR Code® will open the app automatically.
Add Generator to Garage
Do the following to add the generator to your virtual Polaris Garage:
-
From the home screen, press the More button from the bottom menu bar, then click on Garage.
-
Add your generator, by using a Bluetooth® connection.
Using Bluetooth®:-
Turn on the Bluetooth® feature in your smartphone settings.
-
Open the fuel valve and set the engine switch to ON. Do not start the generator.
-
When the generator model number appears on the phone screen, click to add.
-
-
Customize the name of your generator for easy reference within the app.
Features
-
1 Model Number
-
2 Widgets
-
3 Power Button
-
4 Generator Name
-
5 Additional Widgets
-
6 Owner’s Manual
-
7 Accessories Store
-
8 Service and Support Menu
Operation Using the App
The generator utilizes Bluetooth® for remote operation using the Polaris app. To start the generator using the Polaris app, the fuel valve must be open and the engine switch set to ON. Press the power button 3 in the app to start or stop the generator.
The Smart Throttle switch cannot be activated using the Polaris app. To enable the Smart Throttle, manually press the switch on the front control panel of the generator.
The widget information displays generator data obtained through a Bluetooth® connection. If the Bluetooth® connection between the generator and your smartphone is disabled, the widgets will reflect the data from the last known Bluetooth® connection.
Chapter 7: Operation
7.7.1: Safe Operating Precautions
7.7.1.1: Refueling
Thoroughly read the Safety chapter of this manual before handling fuel.
-
Do not spill fuel when filling the fuel tank. Damage caused by spilled fuel is not covered under warranty. Spilled fuel is a fire hazard, caused environmental damage, and can damage paint and plastic. Wipe up spills immediately. Do not fill above bottom of strainer.
-
Refuel in a well ventilated area before starting the engine. If the engine has been running, allow to cool before refueling.
-
Never refuel the engine inside a building where vapors may reach flames or sparks. Keep fuel vapors away from electrical appliances.
-
Do not overfill the fuel tank (there should be no fuel in the filler neck). After refueling, make sure the fuel filler cap is closed properly and securely.
To safely refuel the gas tank, perform the following steps.
-
Ensure fuel valve switch is OFF.
-
Remove fuel tank cap.
-
Fill carefully to avoid spilling fuel on the fuel tank strainer. Do not overfill the fuel tank (there should be no fuel above the upper limit mark).
WARNINGDo not overfill. Fuel overflow may spill onto a hot engine and result in fire or explosion. -
Tighten fuel tank cap securely.
-
Position fuel valve switch to OFF for storage or ON to operate the generator.
-
Move generator away from the fueling site and fuel source before starting the engine.
7.7.2: Starting the Engine
Never operate a generator indoors. Engine exhaust contains carbon monoxide, an odorless, colorless gas that can kill you within minutes. Always use this generator outdoors in a well-ventilated area.
Before starting the engine, take the following precautions:
-
Ensure the generator is away from the fueling source.
-
The generator will vibrate during operation. Place the generator in a dry location and on a flat, level surface.
-
Unplug all power cords and extension cords from the generator.
-
Engage the wheel locks (if installed).
-
Perform an oil, fuel, and air filter check.
7.7.2.1: Electric Start
-
Ensure the generator is away from the fueling source.
-
Unplug all power cords and extension cords from the generator.
-
Turn the fuel valve switch to ON.
-
For a cold engine start, position the choke lever (if equipped) to CLOSE. To restart a warm engine, leave the choke lever in OPEN.
-
To start the generator using electric start, momentarily press down on the top of the ignition switch to the START 1 position. The switch will default back to the RUN 2 position. To stop the engine, press the bottom of the switch to the OFF 3 position.
7.7.2.2: Recoil Start
-
To start the generator using the recoil, lightly pull the starter recoil grip 1 until resistance is felt. Then, firmly pull straight out.
NOTICEDo not allow starter grip to snap back against the generator. Return it gently to prevent damage to the starter.
-
For a cold engine start, pull out the choke lever (if equipped) to CLOSED position.
-
If the choke lever was positioned to CLOSED to start the engine, move it to OPEN as the engine warms up.
7.7.3: Stopping the Engine
In case of emergency, turn ignition switch to OFF position to stop the engine. Under normal conditions, perform the following procedure:
-
Shut off or disconnect all appliances connected to the generator.
-
Turn ignition switch to OFF.
-
Turn fuel valve switch to OFF.
7.7.4: Parallel Operation
Only connect a parallel capable Polaris inverter generator with the approved parallel cable. Attempting to connect a different generator brand in parallel with your generator will void your warranty and could cause severe injury.
Do not start the generators before connecting the parallel cable. Running one generator with the cable connected will cause an overload and require an engine reset.
If the overload indicator light remains on after resetting the generator, stop the engine and wait five minutes before restarting.
-
For continuous operation, do not exceed the combined rated power of the paralleled generators.
-
Do not run the generators longer than 30 minutes at max output.
-
Always stop both engines before connecting or removing the parallel cable.
-
Always remove the parallel cable completely if operating a single unit.
To run generators in parallel, complete the following steps:
-
Ensure both generators are off and fuel valves are closed.
-
Connect the AC parallel cable to the parallel socket 1 on each generator.
-
Ensure all appliances are off and disconnected.
-
Start each generator and then connect the appliance to the parallel cable.
-
Turn on appliance.
7.7.5: AC Operation
-
If an appliance begins to operate abnormally, becomes sluggish, or suddenly stops, immediately shut it off. Disconnect the appliance and determine whether the problem is the appliance or if the rated load capacity of the generator has been exceeded.
-
Ensure the combined electrical rating of the device or appliance does not exceed the maximum allowed by the generator. Never exceed the maximum power rating of the generator. Do not exceed the current limit specified for any one receptacle. Power levels between rated and maximum may be used for no more than 30 minutes.
IMPORTANT: Before connecting a device or power cord to the generator, ensure the device or cord is in good condition and electrical rating does not exceed the maximum amount allowed by the generator.
-
Start engine. See Starting the Engine for additional instruction.
-
Confirm the desired appliance is switched off. Then plug the appliance or extension cord into one of the AC receptacles.
-
Turn on the appliance.
Correct the load by unplugging all appliances from the receptacles and press-in the circuit protector button to reset, followed by the Overload Reset button. AC power will be restored immediately.
AC Capacity
Model | Max Power | Rated Power |
---|---|---|
P3200iEBT | 2800 W | 3200 W |
In case of substantial overloading, the electronic circuit protector will activate. Slightly overloading the generator or running at maximum power operation (30 minutes) may not switch the circuit ON, but will shorten the service life of the generator.
Consider total power requirements of all connected devices. Appliance and power-tool manufacturers typically list rating information near the model or serial number. After plugging in a device, allow the generator to stabilize before plugging in additional items. Always consider generator capacity before plugging in any device.
Typical wattages are listed in the table below. Before plugging any device into the generator, verify the manufacturer-listed wattage on the device.
Wattage Reference Table
Device | Running (Rated) Watts | Additional Starting (Surge) Watts |
---|---|---|
Table Saw / Radial Arm Saw - 10” | 2000 | 2000 |
Space / Wall Heater | 1800 | 0 |
Central Air Conditioning | 1500 | 4500 |
Circular Saw - 7 1/4” | 1400 | 2300 |
Hair Dryer | 300 - 1200 | 0 |
Sump Pump - 1/2 HP | 1050 | 2200 |
Microwave Oven - 100 Watt | 1000 | 1400 |
Coffee Maker | 1000 | 0 |
Garage Door Opener 1/2 HP | 875 | 2350 |
Personal Computer w/ 17” Monitor | 800 | 0 |
Refrigerator | 400 - 800 | 2200 |
Dehumidifier | 650 | 800 |
Color Television - 27” | 500 | 0 |
Electric Drill - 3/8”, 4 amps | 440 | 600 |
Paint Sprayer | 360 | 1080 |
Radio | 300 | 300 |
Oven | 60 | 7500 |
Light Bulb - 75 Watt | 75 | 0 |
Power Management Example
Device | Running (Rated) Watts | Additional Starting (Surge) Watts |
---|---|---|
Radio | 300 W | 300 W |
Space Heater | 1800 W | 0 |
-
2100 = Total Running (Rated) Watts
-
300 = Additional Starting (Surge) Watts
-
2400 = Total Generator Output Required
Ensure the combined electrical rating of the powered device(s) do not exceed the maximum output allowed by the generator. Never exceed the maximum power rating of the generator. Power levels between rated and maximum may be used for no more than 30 minutes.
7.7.6: Air Conditioning Operation
Bring the generator to a normal operating temperature before applying the air conditioning load. Always allow a two-minute wait period when manually cycling an air conditioner off and on.
A longer wait period may be required under unusually hot weather conditions. All other loads should be turned off until the air conditioner has started and is performing normally.
Before applying an air conditioning load, ensure that your generator is rated to handle to the load. Use the table below and the formula included in the AC Operation chapter for reference.
AC Output | Running (Rated) Watts | Additional Starting (Surge) Watts |
---|---|---|
Window AC - 10,000 BTU | 1200 | 3600 |
Window AC - 12,000 BTU | 3250 | 9750 |
Central AC - 10,000 BTU | 1500 | 4500 |
Central AC - 24,000 BTU | 3800 | 11400 |
Central AC - 40,000 BTU | 6000 | 18000 |
Follow the air conditioner manufacturer's instructions for starting and restarting for proper operation. Some air conditioner manufacturers offer a start capacitor as an extra cost option.
The lack of a start capacitor can cause the air conditioner to draw too high a starting current and overload the generator. Contact your air conditioner dealer if you consistently have problems starting your air conditioner with the generator.
7.7.7: Standby Power
7.7.7.1: Connections to a Building Electrical System
Improper connection to a building electrical system can allow current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage.
Additionally, the generator may explode, burn, or cause fires when utility power is restored. Consult the utility company or a qualified electrician prior to making any power connections.
Connections for standby power to a building's electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to back feed into the utility lines.
Such back feed may electrocute utility company workers or others who contact the lines during a power outage; when utility power is restored, the generator may explode, burn, or cause fires in the building's electrical system. Do not connect this generator to an automatic transfer switch. Serious damage to the engine and inverter module may result.
In some areas, generators are lawfully required to be registered with local utility companies. Check local regulations for proper registration and usage procedures.
7.7.7.2: Ground System
-
The portable generator stator winding is isolated from the frame and from the AC receptacle ground pin; and
-
Electrical devices that require a connection between one conductor pin and the grounded receptacle pin may not function properly.
This generator is equipped with a system ground to prevent electrical shock from faulty appliances.
To ground this generator, perform the following steps:
-
Ensure engine is OFF and fuel valve switch is OFF.
-
Using a mallet, drive a grounding rod 4 ft. into the ground.
-
Wrap a length of bare copper grounding wire tightly around the grounding rod or use a grounding clamp.
-
Slightly loosen bolt on ground terminal. Allow enough space to wrap copper wire.
-
Using the other end of the copper wire, tightly wrap the wire around the terminal.
7.7.7.3: System Requirements
There may be federal or state Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.
If the generator is used at a construction site, there may be additional regulatory requirements.
7.7.8: High Altitude Use
7.7.8.1: Carburetor Modification
When carburetor has been modified for high altitude operation, the air-fuel mixture will be too lean for low altitude use and may cause engine damage.
At high altitude, the standard carburetor air-fuel mixture will be excessively rich. Performance will decrease and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude different than that which this engine was certified, for extended periods of time, may increase emissions.
High altitude operation can be improved by specific modifications to the carburetor. If always operating the generator at altitudes above 3000 feet (915 meters), have an authorized Polaris servicing dealer perform the carburetor modification. The engine will meet each emission standard throughout its life when operated at high altitude with the carburetor modifications for high altitude operation.
With the carburetor modification, engine horsepower will decrease by about 3.5% for every 1000 feet (300 meters) increase in altitude. The effect of altitude on horsepower will be greater if no carburetor modification is made.
Altitude Kits
For added convenience, POLARIS offers high altitude kits which optimize performance and fuel consumption at various altitude ranges. For installation instruction, see High Altitude Jets.
Model | Part Number | Description |
---|---|---|
P2000i | 2884865 | K-HIGH,ALT,3-8K,P2000I |
P2500iEBT | 2889540 | K-HIGH,ALT,3-8K,P2500 |
P3200iE / P3200iEBT | 2884866 | K-HIGH,ALT,3-8K,P3200IE |
P5500 / P6500 | 2884867 | K-HIGH,ALT,3-8K,P5500/6500 |
Chapter 8: Emission Control Systems
8.8.1: Source of Emissions
Exhaust gas contains carbon monoxide, nitrous oxide (NOx), and hydrocarbons. It is very important to control the emissions of NOx and hydrocarbons as they are a major contributor to air pollution. Carbon monoxide is a poisonous gas. The emission of fuel vapors is a source of pollution as well. The generator engine utilizes a precise air-fuel ratio and emission control system to reduce the emissions of carbon monoxide, NOx, hydrocarbons, and evaporative fuel emissions.
Polaris utilizes appropriate air-fuel ratios and other emissions control systems to reduce the emissions of carbon monoxide, oxides of nitrogen, and hydrocarbons. In addition, Polaris fuel systems utilize components and control technologies to reduce evaporative emissions.
8.8.2: U.S. Clean Air Acts
Your engine has been designed to meet current Environmental Protection Agency (EPA) clean air standards. The regulations dictate that the manufacturers provide operation and maintenance standards regarding the emission control system. Tune up specifications are provided in the Maintenance section. Adherence to the specified maintenance instructions is essential for your engine to meet the emission control standards.
8.8.3: Alterations
Altering the emission control system may increase emissions beyond the legal limit. Some possible alterations are removal or alteration of any part of the intake, fuel, or exhaust systems.
8.8.4: Problems Affecting Emissions
If aware of any of the following, have the engine inspected and repaired by an authorized Polaris dealer:
-
Hard starting or stalling after starting
-
Rough idle
-
Shut down or backfire after applying an electrical load
-
Afterburning (backfiring)
-
Black exhaust smoke or high fuel consumption
8.8.5: Replacement Parts
The emission control system on the engine was designed, built, and certified to conform to applicable emission regulations. We recommend the use of Polaris Genuine parts whenever maintenance is performed. These original-design replacement parts are manufactured to the same standards as the original parts. The use of replacement parts that are not of the original design and quality may impair the effectiveness of the emission control system.
Aftermarket part manufacturers assume the responsibility that the part will not adversely affect emission performance. The manufacturer or re-builder of the part must certify that use of the part will not result in a failure of the engine to comply with emission regulations.
Chapter 9: Maintenance
9.9.1: Importance of Maintenance
Good maintenance is essential for safe and economical operation. Proper maintenance will also help reduce air pollution. Always follow the recommendations for inspection and maintenance as specified in this manual.
The following chapter includes a periodic maintenance schedule, including proper inspection and maintenance procedure. The maintenance schedule applies to normal operating conditions. This maintenance is essential to the longevity of your generator.
Any qualified repair shop or person may maintain, replace or repair the emission control devices or systems on your generator. POLARIS also recommends POLARIS parts for emissions-related service, however equivalent parts can be used.
It is a potential violation of the Clean Air Act if a part, supplied by an aftermarket parts manufacturer, reduces the effectiveness of the generator’s emission controls. Tampering with emission controls is prohibited by federal law.
Owners are responsible for performing the scheduled maintenance identified in this owner’s manual. Careful periodic maintenance will help keep your generator in safe, reliable condition. Inspect, clean, lubricate, adjust and replace parts as necessary. Other, more difficult tasks, require special tools and expertise provided by an authorized Polaris technician or other qualified mechanic.
If the generator is operated under unusual conditions, such as sustained high load or high temperature, or dusty conditions, consult the servicing dealer for applicable recommendations.
All necessary replacement parts and labor incurred, with the exception of authorized warranty repairs, become the responsibility of the registered owner. If, during the course of the warranty period, part failures occur as a result of owner neglect in performing recommended regular maintenance, the cost of repairs are the responsibility of the owner.
9.9.1.1: Tool Kit
This generator is packaged with a tool kit to help with basic repair and maintenance.
Ref. No. | Tool Description | Quantity |
---|---|---|
1 | Oil Fill Funnel | 1 |
2 | Screwdriver | 1 |
3 | Spark Plug Wrench Handle | 1 |
4 | Spark Plug Wrench | 1 |
9.9.2: Maintenance Safety
Personal safety is critical when attempting to service the generator. Improperly installed or adjusted components can make the generator unstable or dangerous. Improperly installed electrical components can cause engine or electrical systems failure. In either event, damage or serious injury could result. If you do not have the time, tools, and/or expertise necessary to complete a procedure properly, please see your Polaris dealer or other certified technician for service.
Failure to correct a problem before operation and improper maintenance can cause a malfunction resulting in injury or death. Always follow the inspection and maintenance schedules and requirements in this manual.
The following important safety precautions cannot warn of every possible hazard from maintenance. The decision to perform a given task must be evaluated by the individual performing it.
9.9.3: Safety Precautions
Read the safety section of this manual.
Ensure the engine is off before performing any maintenance or repairs to minimize the potential for exposure to the following hazards:
-
Fuel and fire - Avoid flames, sparks, and smoking during service.
-
Carbon monoxide poisoning - Do not operate engine indoors. When operating outdoors, avoid open windows and doors.
-
Burns - Allow the engine and exhaust system to cool before touching. Exercise caution when working around hazardous materials.
-
Injury from moving parts - Avoid running the engine unless specifically instructed.
Follow the instructions and ensure the required tools are used.
Exercise caution when working around gasoline to reduce the possibility of fire or explosion. Use only non-flammable solvents to clean parts. Keep cigarettes, sparks, and flames away from all fuel-related components.
9.9.4: Periodic Maintenance
Prior to performing any maintenance on your generator,
-
Always stop the engine before servicing. Disconnect all devices and extension cords to avoid receiving an electrical shock.
-
Periodic checks and maintenance are very important for keeping the generator in good condition.
-
Inspect, clean, lubricate, adjust, and replace parts as necessary. When inspection reveals the need for replacement parts, use Polaris Genuine parts available from your Polaris dealer.
-
Before beginning any maintenance procedure, read the instructions for the entire procedure. During some procedures, potentially hazardous products may be used. Always follow the instructions and warnings on the product packaging.
9.9.4.1: Periodic Maintenance Chart
Item | Remarks | Pre-Operation Check (daily) | Initial 1 month or 20 hours | Every 3 months or 50 hours | Every 6 months or 100 hours | Every 12 months or 300 hours |
---|---|---|---|---|---|---|
Spark Plug | Check condition. Adjust gap and clean. Replace as needed. | X | ||||
Spark Arrester | Clean the carbon deposits. | X | ||||
Engine Oil | Check the oil level. | X | ||||
Replace oil. | X | X | ||||
Air Filter | Check filter. | X | ||||
Clean. Replace as needed. | X₂ | |||||
Fuel Sediment Cup | Clean. | X | ||||
Fuel Tank and Strainer | Clean. | X₃ | ||||
Valve Clearance | Check and adjust when engine is cold. | X₃ | ||||
Fuel Line | Check fuel line for twists, cracks, or damage. Replace as needed. | Every 2 years (Replace as necessary)₃ | ||||
|
9.9.5: Removing the Maintenance Cover
Use the following steps to remove the generator maintenance cover and gain access to the inner components. Before performing any maintenance, the ignition switch should be positioned to OFF.
-
Position the ignition switch and fuel valve lever to OFF.
-
Remove the two screws 1 from the maintenance cover.
-
Pull down on the lip of the cover 2 to expose the inner components of the generator.
-
Perform maintenance as needed.
-
Upon completion of maintenance, replace cover by inserting the bottom edge into the grooves and replacing the two screws.
9.9.6: Fuel System
Fuel Line Inspection
Inspect the fuel line to ensure absence of twists, cracks, and / or damage. Replace as needed.
Gas Tank Strainer
-
Remove the fuel tank cap.
-
Remove the fuel tank strainer from the fuel tank.
-
Remove any foreign objects or debris from the fuel tank strainer.
-
Inspect the fuel tank strainer for damage. Replace as needed.
-
Install the fuel tank strainer into the fuel tank.
-
Securely tighten the fuel tank cap.
-
Position the fuel valve switch OFF for storage or transport, or ON to run the generator.
9.9.6.1: Fuel Line
Inspect the fuel hose for cracks or damage. Replace as needed. See Fuel System for more information about the fuel system.
9.9.7: Engine Oil
9.9.7.1: Oil Recommendation
Oil Recommendation
POLARIS 5W-30 Generator Oil
Oil directly affects performance and service life. Use a 4-stroke automotive detergent oil, see Oil and Lubricants for recommended oil. Other viscosities may be used when the applicable average temperature is within the recommended range.
The SAE oil viscosity and service category are in the API label on the oil container. Polaris recommends the use of API service category “SJ” or later, equivalent oil.
9.9.7.2: Oil Level Inspection
-
Failure to use the proper 4-stroke engine oil may result in engine damage.
-
Using non-recommended oil may cause serious engine damage. Never substitute or mix oil brands.
-
Inspect the oil level before each use with the engine stopped and the generator on a level surface.
-
Remove the oil filler cap / dipstick and wipe it clean.
-
Insert the dipstick into filler neck, without screwing it in, to inspect the oil level.
-
Remove the dipstick and verify that the oil is at the upper limit. Add additional oil and inspect the level as needed until the upper limit has been reached.
-
Re-install the dipstick. Use a clean shop rag to clean any spilled oil.
-
Do not tilt generator when adding engine oil. This could result in overfilling and damage to the engine.
-
Use high quality 4-stroke engine oil, certified to meet or exceed API standard SG, SF, SAE ratings with strong detergents. Using non-detergent or 2-stroke oil could shorten the engine’s working life.
-
Do not mix different engine oils.
-
Handle and store the engine oil with care, avoid getting dirt or dust into the engine oil.
-
Before the engine oil falls below the safety margin, the low oil alert system ill automatically shut off the engine. The low oil light (RED) will illuminate.
-
To avoid the inconvenience of unexpected engine shutdown, check oil level before each use.
9.9.7.3: Oil Change
-
Start the engine and allow it to run for a few minutes. Stop the engine.
-
Position the fuel valve switch to OFF.
-
Elevate the generator several inches above the ground.
-
Open the oil access door to expose oil drain 1.
-
Remove the oil filler cap / dipstick.
-
Place a drain pan under the generator.
-
Remove the drain bolt 2 and sealing washer 3 from the bottom of the generator.
-
Drain the used oil into a sealed container and take it to a recycling center. Do not discard the oil in a trash can, dump it on the ground, or pour it down the drain.
-
Re-install the washer and drain bolt.
-
Place provided funnel into fill valve.
-
Fill oil to the high limit mark on the dipstick. Ensure that the oil level does not rise past the threading of the cap.
CAPACITYPolaris 5W-30 Generator Oil
19.6 floz (0.58 l)
-
Remove funnel and re-install the dipstick. Do not screw in.
-
Start the engine and let run for 1 or 2 minutes. Stop the engine and check for leaks.
-
Re-check the oil level on the dipstick and add oil as needed to bring the level to the upper mark on the dipstick.
-
Re-install the dipstick.
-
Re-install oil access door securely.
-
Wash hands with soap and water after handling used oil.
9.9.8: High Altitude Jets
Altitude Kits
Model | Part Number | Description |
---|---|---|
P2000i | 2884865 | K-HIGH,ALT,3-8K,P2000I |
P3200iE / P3200iEBT | 2884866 | K-HIGH,ALT,3-8K,P3200IE |
P5500 / P6500 | 2884867 | K-HIGH,ALT,3-8K,P5500/6500 |
Altitude Jet Specifications
Model | Engine | Altitude | Altitude Jet Mark |
---|---|---|---|
P2000i | 79cc | 3000-6000 ft | 68 |
6000-8000 ft | 67 | ||
P3200iE / P3200iEBT | 208cc | 3000-6000 ft | 74 |
6000-8000 ft | 73 | ||
P5500 | 389cc | 3000-6000 ft | 103 |
6000-8000 ft | 101 | ||
P6500 | 420cc | 3000-6000 ft | 107 |
6000-8000 ft | 105 |
Jet Installation
To change the carburetor main jet, follow this procedure:
-
Turn off the fuel supply.
-
Remove the maintenance cover.
-
Access the carburetor drain screw. Drain the fuel from the carburetor into a suitable container.
-
Remove the float bowl and chamber bolt.
-
Remove the main jet from the carburetor.
-
Install the correct main jet for the altitude in which the generator is operating. Do not over-tighten the jet.
-
Re-install the float bowl and chamber bolt.
-
Close carburetor drain screw.
-
Re-install the maintenance cover.
-
Turn on fuel supply. Start generator and let engine run for several minutes.
-
Turn off generator. Verify there are no fuel leaks.
9.9.9: Air Filter
-
Detach maintenance cover.
-
If necessary, move fuel hoses out of the way to expose air box.
-
Remove two screws 1 to open the air box.
-
Extract air filter from box.
-
If filter is dirty or torn, replace it with a new one.
-
Re-install air box cover and secure with screws.
-
Move fuel hoses back into position.
-
Re-install the maintenance cover.
Foam Filters
If using a foam air filter, follow the steps below to clean the filter before replacing it in the air box.
-
Submerge the filter in a solution of warm water and household detergent.
-
Let the filter soak in the solution for a few minutes and then squeeze out the excess water.
-
Repeat step 2 several times to ensure the water coming from the filter is clean. Then let the filter dry completely.
-
Once dry, pour air filter oil onto the filter and distribute evenly. Be sure to rid the filter of excess oil.
NOTICEThe use of air filter oil allows the filter to catch even the smallest particles of dirt and dust. -
If at any point during the cleaning process the filter becomes damaged, then it must be replaced prior to operating your generator.
9.9.10: Spark Plug
9.9.10.1: Spark Plug Inspection
Using a non-recommended spark plug can result in serious engine damage. Always use recommended spark plugs. Refer to the Specification section for the recommended spark plug type. Always torque spark plugs to the specification.
In order to service the spark plug, the provided spark plug wrench is required.
-
Open the maintenance cover.
-
Remove the spark plug cap 1.
-
Clean any dirt from around the base of the spark plug.
-
Using the provided park plug wrench, remove the spark plug.
-
Inspect the electrode for wear and carbon buildup. Look for a sharp outer edge with no rounding or erosion of the electrode.
-
Inspect spark plug. Replace if electrodes are worn or if insulator is cracked, chipped, or fouled.
-
Clean the spark plug with a wire brush if it is to be reused.
9.9.10.1.1: Normal Plug
The normal insulator tip is gray, tan or light brown. There will be few combustion deposits. The electrodes are not burned or eroded.
This indicates the proper type and heat range for the engine and the service.
9.9.10.1.2: Wet Fouled Plug
The wet fouled insulator tip is black. A damp oil film covers the firing end. There may be a carbon layer over the entire nose. Generally, the electrodes are not worn. Fouling may be caused by excessive oil or by frequent short trips, especially in cold weather.
9.9.10.2: Spark Plug Replacement
-
Open the maintenance cover.
-
Remove the spark plug cap.
-
Clean any dirt from around the base of the spark plug.
-
Using the provided park plug wrench, remove the spark plug.
-
Using a wire-type feeler gauge, measure the spark plug electrode gap. If necessary, correct the gap by carefully bending the side electrode.
MEASUREMENTSpark Plug Gap
0.024- 0.028 in (0.6-0.7 mm)
-
Ensure the spark plug sealing washer is in good condition and thread the spark plug in by hand to prevent cross-threading.
-
After a new spark plug has been seated by hand, it should be tightened 1/2 turn with a wrench to compress the sealing washer. If a used plug is being reinstalled, it should only require 1/8 to 1/4 turn after being seated.
-
Re-install the spark plug cap and close the maintenance cover.
NOTICEA loose spark plug can overheat and damage the engine. Over tightening the spark plug can damage the plug threads.
Never use a spark plug with an improper heat range.
9.9.11: Spark Arrester
The spark arrester is located on the end of the muffler.
Generator exhaust system gets hot enough to ignite some materials and burn skin if touched.
Allow generator and exhaust to cool before performing spark arrestor maintenance.
Before performing any inspection or maintenance on the battery, ignition switch should be positioned to OFF.
Removing the Back Panel
The back panel and rear handle of the generator must be removed in order to access the muffler and the spark arrester. Allow the generator to fully cool before touching internal components.
-
Detach rear panel by removing the four screws 5.
Removing the Spark Arrester
-
Remove screw 6 holding the spark arrester to the muffler.
-
Pull the end cap off to remove the arrester screen.
-
Clean the spark arrestor with a stiff wire brush.
-
Replace if the wire mesh is perforated or torn.
-
Reinstall screen and cap. Secure cap to the muffler with the screw.
9.9.12: Battery
This generator uses a lithium ion battery. The overheating of lithium batteries may result in a fire or explosion, leading to severe injury or death. Stop charging if the battery becomes very warm to the touch. Allow battery to completely cool before resuming charging.
Always keep battery terminals and connections free of corrosion.
Do not place batteries in direct sunlight or keep them in hot vehicles. Keep batteries at room temperature.
If cleaning is necessary, remove corrosion with a stiff wire brush. Wash with a solution of one tablespoon baking soda and one cup water. Rinse well with tap water and dry off with clean shop towels.
Always store batteries away from anything that can catch fire.
To access the battery 1, remove the maintenance panel.
9.9.12.1: Battery Removal
-
The battery is located at the front of the generator, just below the control panel.
-
To expose the battery, detach the battery access panel by removing the two screws.
-
Disconnect the battery hold-down strap.
-
Lift the battery 1 out of the generator.
-
Disconnect the black (negative) battery cable first by removing the M5 screw 2.
-
Disconnect the red (positive) battery cable last by removing the M5 screw 2.
9.9.12.2: Battery Installation
Using a new battery that has not been fully charged can damage the battery and result in a shorter life. It can also hinder generator performance. Follow the instructions in the Battery Charging section before installing the battery.
-
Ensure that the battery is fully charged.
-
Place the battery in the battery holder.
-
Coat the terminals with dielectric grease or petroleum jelly.
-
Secure the battery hold-down strap.
-
Connect and tighten the red (positive) cable first.
-
Connect and tighten the black (negative) cable last.
-
Verify that cables are properly routed. Cables should be safely tucked away at the front and rear of the battery.
-
Re-install the battery access panel.
9.9.12.3: Battery Maintenance and Charging
Battery Storage
If storing your generator for an extended amount of time, Polaris recommends starting the generator once a month to charge the battery. Use the table below to determine how long the generator must run to fully charge the battery depending on the battery’s current state of charge. Always verify battery condition before and 1-2 hours after charge completion. Store the generator and battery in a cool, dry place.
State of Charge | Voltage (DC) | Action |
100% |
13 - 13.3 V |
No action; check monthly |
75%-100% |
12.7 - 13 V |
May need charge; if no charge given, check again in 2 weeks |
50%-75% |
12.3 - 12.7 V |
Needs charge |
25%-50% |
12 - 12.3 V |
Needs charge |
0%-25% |
12 V or less |
Needs charge |
9.9.13: Specifications
9.9.13.1: Cleaning the Generator
To clean the generator, wipe down with a dry shop rag. Always use clean cloths and pads for cleaning and polishing.
If an informational or graphic label becomes illegible or comes off, contact your POLARIS dealer to procure a replacement. Replacement safety labels are provided by POLARIS at no charge.
9.9.13.2: Storage Preparation
Gasoline is highly flammable and explosive and can cause serious injury. Stop the engine and keep heat, sparks, and flame away. Only handle fuel outdoors. Wipe up spills immediately.
Long-term storage of the generator will require some additional preventative measures to guard against deterioration. If fuel is kept in the generator, run the engine for at least 30 minutes each month to ensure an easy start during the next operation. Be sure the storage area is free of excessive humidity and dust.
-
If the generator will be stored with fuel, add fuel stabilizer. See Stabilizing the Fuel.
-
If the generator will be stored dry of fuel, drain all fuel and fog the engine prior to storage. See Draining the Fuel and Fogging the Engine.
-
Change engine oil. See Oil Change.
-
Remove battery and store in cool, dry location. Use a battery trickle charger to maintain battery charge.
-
Clean exterior of the generator with a clean, dry cloth.
WARNINGDo not pour water directly on to the generator or wash it with water. -
Turn fuel valve lever to OFF.
9.9.13.2.1: Accessing the Fuel Tank
-
Remove the fuel tank cap 1.
-
Remove debris as needed.
-
When maintenance is complete, re-install the fuel tank strainer into the fuel tank.
-
Securely tighten the fuel tank cap.
9.9.13.2.2: Stabilizing the Fuel
This procedure applies if keeping gasoline in fuel tank during storage. Drain the carburetor bowl prior to any storage period longer than 30 days. See Lubricants and Fluids for suitable fuel stabilizer.
-
Access the fuel tank.
-
Add a suitable fuel stabilizer.
9.9.13.2.3: Draining the Fuel
Do not spill fuel when draining the fuel tank. Spilled fuel is a fire hazard, causes environmental damage, and can cause damage to paint and plastic. Wipe up spills immediately.
Perform this procedure if fuel will NOT be kept in the fuel tank during storage or before transportation.
-
Access the fuel tank and remove the gas cap.
-
Empty fuel tank into an approved gasoline container. Polaris recommends using a commercially available gasoline hand pump to empty the tank. Do not use an electric pump.
-
Re-install gas cap onto the tank and securely tighten.
-
Remove the maintenance cover.
-
Place drain pan outside generator.
-
Pull the fuel hose out of the enclosure and into the drain pan.
-
Loosen carburetor drain screw 1.
-
Turn fuel valve switch to ON and drain gasoline into pan.
-
Pour gasoline from pan into a suitable container.
9.9.13.2.4: Fogging the Engine
-
Turn the ignition key to the OFF position.
-
Remove the spark plug cap 1.
-
Using the provided park plug wrench, remove the spark plug.
-
Spray fogging oil into the cylinder. Crank the engine several revolutions to distribute the oil and then reinstall the spark plug.
-
Ensure that the spark plug sealing washer is in good condition and hand-tighten the spark plug to prevent cross-threading.
-
Using a spark plug wrench, carefully tighten the spark plug. Torque the spark plug to specification, see Spark Plug Inspection.
-
Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed. Storing the engine in this position will help protect it from internal corrosion.
-
Re-install the spark plug cap 1.
-
Cover the generator and store indoors, in a dry, well-ventilated area.
Polaris Fogging Oil
(12 oz aerosol can)
Part Number: 2870791
9.9.13.2.5: Battery Storage
Recharge the battery once a month or use a trickle charger to maintain battery charge. See Battery Storage for additional instruction.
9.9.13.2.6: Storage Precautions
-
Select a well-ventilated storage area away from any flame-operated appliance (i.e., furnace, water heater, or clothes dryer). Avoid areas containing a spark-producing electric motor, or where power tools are operated.
-
Be sure storage area is free of excessive humidity and dust.
-
Place generator on a level surface. Tilting can cause fuel or oil leakage.
-
With the engine and exhaust system cooled, cover the generator to prevent dust contamination. Do not use a plastic sheet as a dust cover. Nonporous covers trap moisture around the generator, promoting rust and corrosion.
-
Position fuel tank cap vent lever to OFF to reduce leakage possibilities.
9.9.13.2.7: Removal from Storage
-
Re-install battery. See Battery Installation.
-
Perform Pre-Operation Inspection on Pre-Operation Inspection.
-
If fuel was drained during storage preparation, fill tank with fresh gasoline. See Refueling. If gasoline is stored in a container, ensure the gasoline is fresh. Gasoline oxidizes and deteriorates over time, causing hard starting.
9.9.14: Transporting the Generator
-
If the generator has been used, allow it to cool for at least 15 minutes before loading it on the transport vehicle.
-
Drain the fuel from tank and carburetor. See Draining the Fuel.
-
Position the ignition switch to OFF.
-
Position the fuel valve switch to OFF.
-
Keep generator level and upright during transport.
10.1 P3200iEBT
Specifications |
||
---|---|---|
ALTERNATOR | ||
Model | P3200iEBT | |
AC Output Voltage |
120V | |
Rated Output |
2800 W | |
Maximum Output |
3200 W | |
Frequency |
60 Hz |
|
Type |
Inverter |
|
ENGINE | ||
Type | 4-stroke, OHV Air-cooled, Single Cylinder | |
Displacement | 208cc | |
Engine Speed | 2800-3600 rpm | |
Cooling System | Forced Air | |
Fuel Type | Unleaded Gasoline | |
Fuel Tank Capacity | 1.95 gal (7.4 L) | |
Engine Oil | Polaris 5W-30 Generator Oil | |
Engine Oil Capacity | 19.6 fl oz (0.58 L) | |
Intake Valve Clearance-Cold | Refer to Service Manual | |
Exhaust Valve Clearance-Cold | Refer to Service Manual | |
Spark Plug Gap | WR7DC .024 - .028in. (0.6 - 0.7mm) | |
GENERATOR | ||
Fuel | 87 Octane (Up to 10% Oxygenated) | |
Fuel Tank Capacity | 1.95 gal (7.4 L) | |
Noise Level dB(A) range* | 67 - 72 dB(A) *dB(A) measured outdoors at 23 feet (7 meters) from control panel side | |
Starting System | Mobile App, Electric, and Recoil Backup | |
Dimensions (L x W x H) | 25.2 in (640.08 mm) 19.3 in (490.22 mm) 19.7 in (500.38 mm) |
|
Weight | 96 lbs (43.5 kg) | |
Full Tank Run Time Hours @ 100% Load | 3.5 hrs | |
Max. Altitude (Unmodified) | 3280 ft (1000 m) | |
Parallel Function | Yes |
Chapter 10: POLARIS Products
10.10.1: Oil and Lubricants
Polaris Products | |
---|---|
PART NUMBER | DESCRIPTION |
ENGINE OIL | |
2879383 | Polaris 5W-30 Small Engine Oil (1 Quart) (32 oz.) |
ADDITIVES | |
2881413 | Premium Carbon Clean / Fuel Stabilizer (12 oz.) (12 count) |
2870791 | Polaris Fogging Oil (12 oz. Aerosol Can) |
Chapter 11: Troubleshooting
11.11.1: Engine Will Not Turn Over
Possible Cause | Solution |
---|---|
Starter recoil damage | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
Low battery voltage | Recharge the battery to 12.8V DC or restart the engine manually to charge the battery. |
Starter motor damaged | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
Internal engine damage | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
11.11.2: Engine Turns Over, But Will Not Start
Possible Cause | Solution |
---|---|
Engine is flooded | Wait 15 minutes before restarting. Use recoil. |
Out of fuel | Refuel. |
Low Oil | Repeat Pre-operation Inspection. |
Water is present in fuel | Drain fuel system and refuel. |
Old or non-recommended fuel | Drain fuel system and refuel. |
Fouled or defective spark plug | Inspect spark plug and replace, if needed. |
No spark to spark plug | Inspect spark plug. Verify engine switch is ON. |
Water or fuel in crankcase | Take the generator to an authorized Polaris servicing dealer or refer to service manual. |
Low battery voltage | Recharge the battery to 12.8V DC or start the engine manually to recharge the battery. |
Mechanical failure | Take the generator to an authorized Polaris servicing dealer or refer to service manual. |
Fuel valve is OFF | Turn fuel valve ON. |
11.11.3: Engine Lacks Power
Possible Cause | Solution |
---|---|
Air filter restricted | Clean or replace air filter. |
Bad fuel; generator stored without treating or draining gasoline, or refueled with bad gasoline | Drain the fuel system and refuel. |
Mechanical failure | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
11.11.4: Engine Backfires
Possible Causes | Solution |
---|---|
Weak spark from spark plug | Inspect, clean, and / or replace spark plug. |
Incorrect spark plug gap or heat range | Set gap to specification or replace spark plug. |
Old or non-recommended fuel | Drain the fuel system and refuel. |
Incorrectly installed spark plug wires | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
Incorrect ignition timing | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
Mechanical failure | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
Loose ignition connections | Check all connections and tighten. |
Water present in fuel | Drain the fuel system and refuel. |
11.11.5: Engine Pings or Knocks
Possible Cause | Solution |
---|---|
Poor quality or low octane fuel | Drain the fuel system and refuel. |
Incorrect ignition timing | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
Incorrect spark plug gap or heat range | Set gap to specification or replace spark plugs. |
11.11.6: Engine Runs Irregularly, Stalls or Misfires
Possible Cause | Solutions |
---|---|
Fouled or defective spark plug | Inspect, clean, and / or replace spark plug. |
Worn or defective spark plug | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
Incorrect spark plug gap or heat range | Set gap to specification or replace spark plug. |
Loose ignition connections | Check all connections and tighten. |
Water present in fuel | Drain the fuel system and refuel. |
Low battery voltage | Recharge battery to 12.8 Vdc or start the engine manually to recharge the battery. |
Kinked or plugged fuel tank vent line | Inspect and replace. |
Incorrect fuel | Drain the fuel system and refuel. |
Economy throttle control malfunction | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
Other mechanical failure | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
11.11.6.1: Lean Fuel
Possible Lean Fuel Cause | Solution |
---|---|
Low or contaminated fuel | Add fuel, or drain fuel system and refuel. |
Kinked or plugged fuel tank vent | Inspect and replace. |
Low octane fuel | Drain fuel system and refuel. |
Carburetor jetting incorrectly | Take generator to an authorized Polaris servicing dealer or refer to service manual. |
11.11.6.2: Rich Fuel
Possible Rich Fuel Cause | Solution |
---|---|
Incorrect fuel | Drain fuel system and refuel. |
Stopping / starting without adequate warm-up | Allow engine to warm up before operating and / or stopping. |
Incorrect spark plug | Inspect and replace with correct plug. |
Clogged air filter | Inspect and clean or replace. |
11.11.7: Engine Stops or Loses Power
Possible Cause | Solution |
---|---|
Out of fuel | Refuel. |
Fouled, worn, incorrect, or defective spark plug; incorrect spark plug gap or heat range | Inspect, clean, and / or replace the spark plug / set the spark plug gap to specification. |
Loose ignition connections | Check all connections and tighten. |
Water present in fuel / incorrect fuel | Drain the fuel system and refuel. |
Kinked or plugged fuel tank vent line | Inspect and replace. |
Economy throttle control malfunction | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
No / low oil in the engine | Check / replace oil. |
Clogged air filter | Clean or replace the air filter. |
Mechanical failure | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
11.11.8: No Power at AC Receptacles
Possible Cause | Solution |
---|---|
Output indicator is OFF, and overload indicator is ON | Take the generator to a Polaris servicing dealer or refer to the service manual. |
AC circuit protector tripped | Check AC load and reset circuit protector. |
Overload protector tripped | Push the Overload Restart switch. |
Faulty power tool or appliance | Replace or repair power tool or appliance; stop and restart the engine. |
Faulty generator | Take the generator to an authorized Polaris servicing dealer or refer to the service manual. |
Chapter 12: Warranty
12.12.1: Limited Warranty
POLARIS Sales Inc., 2100 Highway 55, Medina, MN 55340 gives a THREE YEAR LIMITED WARRANTY for consumer use and a ONE YEAR LIMITED WARRANTY for commercial use on all components of your POLARIS generator against defects in material or workmanship. This warranty covers parts and labor charges for repair or replacement of defective parts and begins on the date of purchase.
This warranty is transferable to another owner during the warranty period through a POLARIS dealer, but any such transfer will not extend the original term of the warranty.
12.12.2: Registration
The Warranty Registration Form must be completed by the purchaser and submitted to POLARIS within ten days of purchase. Upon receipt of this registration, POLARIS will record the registration information for warranty. No verification of registration will be sent to the purchaser. Registration cards can be found in the original box of the product and can be mailed into POLARIS at the address listed on the card, or completed at www.polarispower.com/warranty. NO WARRANTY COVERAGE WILL BE ALLOWED UNLESS YOUR GENERATOR IS REGISTERED WITH POLARIS.
12.12.3: Spark Arrestor Warranty
The manufacturer will warrant this product to maintain an acceptable spark arresting effectiveness for a minimum of 1,000 hours, subject to normal use, with maintenance and mounting in accordance with the manufacturing recommendation.
12.12.4: Warranty Coverage And Exclusions
12.12.4.1: Limitation of Warranties and Remedies
This POLARIS limited warranty excludes any failures that are not caused by a defect in material or workmanship. This warranty does not cover claims of defective design. This warranty also does not cover accidental damage, normal wear and tear, abuse or improper handling. This warranty also does not cover any unit that has been altered structurally, modified, neglected, improperly maintained, or used for purposes other than for which it was designed.
This warranty excludes damages or failures resulting from improper lubrication; improper engine timing; improper fuel; surface imperfections caused by external stress, heat, cold or contamination; operator error or abuse; improper component alignment, tension, adjustment or altitude compensation; failure due to snow, water, dirt or other foreign substance ingestion/contamination; improper maintenance; modified components; use of aftermarket components resulting in failure; unauthorized repairs; repairs made after the warranty period expires or by an unauthorized repair center. This warranty will not apply to any product which has been damaged by abuse, accident, fire, or any other casualty not determined to be a defect or materials or workmanship.
12.12.4.2: Lubricants and Fluids
-
Mixing oil brands or using non-recommended oil may cause engine damage. We recommend the use of POLARIS engine oil.
-
Damage or failure resulting from the use of non-recommended lubricants or fluids is not covered by this warranty.
Some items are considered “consumable” meaning they are considered part of normal maintenance or part of completing an effective repair. The following items are excluded from warranty coverage in the event of a warranty claim: spark plugs, filters, sealants, and lubricants.
This warranty does not allow for coverage of personal loss and provides no coverage for mileage, transportation costs, shipping or handling fees, product pick-up or delivery, replacement rentals, loss of product use or profits, or loss of vacation or personal time.
THE EXCLUSIVE REMEDY FOR BREACH OF THIS WARRANTY SHALL BE, AT POLARIS' OPTION, REPAIR OR REPLACEMENT OF ANY DEFECTIVE MATERIALS, COMPONENTS, OR PRODUCTS. THE REMEDIES SET FORTH IN THIS WARRANTY ARE THE ONLY REMEDIES AVAILABLE TO ANY PERSON FOR BREACH OF THIS WARRANTY. POLARIS SHALL HAVE NO LIABILITY TO ANY PERSON FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY DESCRIPTION, WHETHER ARISING OUT OF EXPRESS OR IMPLIED WARRANTY OR ANY OTHER CONTRACT, NEGLIGENCE, OR OTHER TORT OR OTHERWISE. THIS EXCLUSION OF CONSEQUENTIAL, INCIDENTAL, AND SPECIAL DAMAGES IS INDEPENDENT FROM AND SHALL SURVIVE ANY FINDING THAT THE EXCLUSIVE REMEDY FAILED OF ITS ESSENTIAL PURPOSE.
THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE IS EXCLUDED FROM THIS LIMITED WARRANTY. ALL OTHER IMPLIED WARRANTIES (INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTY OF MERCHANTABILITY) ARE LIMITED IN DURATION TO THE ABOVE SIX MONTH WARRANTY PERIOD. POLARIS DISCLAIMS ALL EXPRESS WARRANTIES NOT STATED IN THIS WARRANTY. SOME STATES DO NOT PERMIT THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR ALLOW LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU IF INCONSISTENT WITH CONTROLLING STATE LAW.
12.12.5: How To Obtain Warranty Service
If your generator requires warranty service, you must take it to a POLARIS Servicing Dealer. When requesting warranty service you must present your copy of the Warranty Registration from the dealer. (THE COST OF TRANSPORTATION TO AND FROM THE DEALER IS YOUR RESPONSIBILITY). POLARIS suggests that you use your original selling dealer; however, you may use any POLARIS Servicing Dealer to perform warranty service.
12.12.5.1: In the Country where your product was purchased:
Warranty or Service Bulletin repairs must be done by an authorized POLARIS dealer, or other qualified person. If you move or are traveling within the country where your product was purchased, Warranty and Service Bulletin repairs may be requested from any authorized POLARIS dealer, or other qualified person, that sells the same line as your product.
12.12.5.2: Outside the Country where your product was purchased:
If you are traveling temporarily outside the country where your product was purchased, you should take your product to an authorized POLARIS dealer, or other qualified person. You must show the dealer photo identification from the country of the selling dealer's authorized location as proof of residence. Upon residence verification, the servicing dealer will be authorized to perform the warranty repair.
12.12.5.3: If you move:
If you move to another country, be sure to contact POLARIS Customer Assistance and the customs department of the destination country before you move. Product importation rules vary considerably from country to country. You may be required to present documentation of your move to POLARIS in order to continue your warranty coverage. You may also be required to obtain documentation from POLARIS in order to register your product in your new country. You should warranty register your product at a local POLARIS dealer in your new country immediately after you move to continue your warranty coverage and to ensure that you receive information and notices regarding your product.
12.12.5.4: If you purchase from a private party:
If you purchase a POLARIS product from a private party, to be kept and used outside of the country in which the product was originally purchased, all warranty coverage will be denied. You must nonetheless register your product under your name and address with a local POLARIS dealer in your country to ensure that you receive safety information and notices regarding your product.
12.12.6: Exported Products
EXCEPT WHERE SPECIFICALLY REQUIRED BY LAW, THERE IS NO WARRANTY OR SERVICE BULLETIN COVERAGE ON THIS PRODUCT IF IT IS SOLD OUTSIDE THE COUNTRY OF THE SELLING DEALER'S AUTHORIZED LOCATION. This policy does not apply to products that have received authorization for export from POLARIS. Dealers may not give authorization for export. You should consult an authorized dealer to determine this product's warranty or service coverage if you have any questions. This policy does not apply to products registered to government officials or military personnel on assignment outside the country of the selling dealer's authorized location. This policy does not apply to Safety Bulletins.
12.12.7: Notice
If your product is registered outside of the country where it was purchased and you have not followed the procedure set above, your product will no longer be eligible for warranty or service bulletin coverage of any kind, other than safety bulletins. Products registered to government officials or military personnel on assignment outside of the country where the product was purchased will continue to be covered by the Limited Warranty.
Please work with your dealer to resolve any warranty issues. Dealership contacts can be found via this website, if needed:
www.polaris.com/en-us/contact
Should your dealer require any additional assistance, they will contact the appropriate person at POLARIS.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or in different countries. If any of the above terms are void because of federal, state, local law, all other warranty terms will remain in effect.
For questions call POLARIS Customer Assistance:
United States & Canada: 1-800-POLARIS (1-800-765-2747)
French: 1-800-268-6334
12.12.8: Emission Control System Limited Warranty
This emissions limited warranty is in addition to the POLARIS standard limited warranty for your product.
YOUR WARRANTY RIGHTS AND OBLIGATIONS
UNITED STATES & CANADA
POLARIS must warrant the emission control system on your generator for the periods of time listed in the Warranty Coverage section below provided there has been no abuse, neglect or improper maintenance of your small off-road engine. POLARIS Industries Inc. warrants that at the time it is first purchased, this emissions-certified product is designed, built and equipped to conform with the requirements of the U.S. Environmental Protection Agency and the Environment and Climate Change Canada regulations. POLARIS warrants that the product is free from defects in materials or workmanship that would cause it to fail to meet these regulations. Where a warrantable condition exists, POLARIS will repair your generator engine at no cost to you including diagnosis, parts and labor.
Your emission control system may include parts such as the carburetor or fuel-injection system, the ignition system, and catalytic converter. Also included may be hoses, belts, connectors and other emission-related assemblies. Additional covered parts are listed in the Warranty Coverage section below.
WARRANTY COVERAGE
The warranty period for this emission-certified product sold in the United States and Canada starts on the date the equipment is delivered to the original retail purchaser and continues for a period of 24 calendar months. This warranty is transferable to each subsequent purchaser for the duration of the warranty period.
This emissions limited warranty covers components whose failure increases emissions, and it covers components of systems whose only purpose is to control emissions. Repairing or replacing other components not covered by this warranty is the responsibility of the product owner. This emissions limited warranty does not cover components whose failure does not increase the product’s regulated emissions.
For exhaust emissions, emission-related components include any engine parts related to the following systems:
-
Air-induction system
-
Fuel system
-
Ignition system
-
Exhaust gas recirculation system
The following parts are also considered emission-related components for exhaust emissions:
-
Aftertreatment devices
-
Crankcase ventilation valves
-
Sensors
-
Electronic control units
The following parts are considered emission-related components for evaporation emissions:
-
Fuel Tank
-
Fuel Cap
-
Fuel Line
-
Fuel Line Fittings
-
Clamps*
-
Pressure Relief Valves*
-
Control Valves*
-
Control Solenoids*
-
Electronic Controls*
-
Vacuum Control Diaphragms*
-
Control Cables*
-
Control Linkages*
-
Purge Valves
-
Vapor Hoses
-
Liquid/Vapor Separator
-
Carbon Canister
-
Canister Mounting Brackets
-
Carburetor Purge Port Connector
*As related to the evaporative emission control system
Emission-related components also include any other part whose only purpose is to reduce emissions or whose failure will increase emissions without significantly degrading engine/equipment performance.
If any emissions related component on your engine is defective, POLARIS will repair or replace the defective component without any charge for diagnosis, parts, or labor. All defective parts replaced under this warranty become the property of POLARIS.
EXCLUSIONS
This limited warranty excludes failures not caused by a defect in material or workmanship. This limited warranty does not cover damage due to accidents, abuse or improper handling, maintenance or use. This limited warranty also does not cover any engine that has been structurally altered. This limited warranty also does not cover physical damage, corrosion or defects caused by fire, explosions or other similar causes beyond the control of POLARIS. Owners are responsible for performing the scheduled maintenance identified in the owner's manual. POLARIS may deny warranty claims for failures that have been caused by the owner's or operator’s improper maintenance or use, by accidents for which POLARIS has no responsibility, or by acts of God.
TO OBTAIN WARRANTY SERVICE
The generator engine owner must, at their own expense, take the small off-road engine, or the product on which it is installed, along with the sales registration card or other proof of original purchase date, to any qualified repair shop or qualified person. Any qualified repair shop or person may maintain, replace, or repair the emission control devices or systems on your product. An authorized POLARIS dealer can perform any service that may be necessary for your product. POLARIS also recommends POLARIS parts, however equivalent parts may be used for such service. It is a potential violation of the Clean Air act if a part supplied by an aftermarket parts manufacturer reduces the effectiveness of the product’s emission controls. Tampering with emission controls is prohibited by federal law.
DISCLAIMER
The exclusive remedy for breach of this limited warranty shall be, at the exclusive option of POLARIS, repair or replacement of any defective materials, components or products. THE REMEDIES SET FORTH IN THIS LIMITED WARRANTY ARE THE ONLY REMEDIES AVAILABLE TO ANY PERSON FOR BREACH OF THIS WARRANTY. POLARIS SHALL HAVE NO LIABILITY TO ANY PERSON FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES OF ANY DESCRIPTION, WHETHER ARISING OUT OF EXPRESS OR IMPLIED WARRANTY OR ANY OTHER CONTRACT, NEGLIGENCE OR OTHER TORT OR OTHERWISE. THIS EXCLUSION OF CONSEQUENTIAL, INCIDENTAL, AND SPECIAL DAMAGES IS INDEPENDENT FROM AND SHALL SURVIVE ANY FINDING THAT THE EXCLUSIVE REMEDY FAILED OF ITS ESSENTIAL PURPOSE.
ALL IMPLIED WARRANTIES (INCLUDING BUT NOT LIMITED TO ANY
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE) ARE LIMITED IN DURATION TO THE WARRANTY
PERIOD DESCRIBED HEREIN. POLARIS DISCLAIMS ALL EXPRESS
WARRANTIES NOT STATED IN THIS WARRANTY. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitation may
not apply if it is inconsistent with the controlling state law.
SPARK ARRESTOR LIMITED WARRANTY
POLARIS warrants that the spark arrestor in this product will meet the efficiency requirements of USFS standard 5100-1C for at least 1000 hours when subjected to normal use and when maintenance and installation are in accordance with POLARIS recommendations.
CONTACT INFORMATION
If you have any questions regarding your warranty rights and responsibilities, please contact POLARIS Customer Assistance at 1-800-POLARIS (1-800-765-2747).
United States & Canada: 1-800-POLARIS (1-800-765-2747)
French: 1-800-268-6334
Chapter 13: Maintenance Log
13.13.1: Maintenance Log
Use the following chart to record periodic maintenance.
DATE | HOURS | TECHNICIAN | SERVICE PERFORMED / COMMENTS |
---|---|---|---|