Battery Charging
The following battery charging instructions apply only to the installation of a sealed battery. Read all instructions before proceeding with the installation of this battery.
The sealed battery is already filled with electrolyte and has been sealed and fully charged at the factory. Never pry the sealing strip off or add any other fluid to this battery.
The single most important thing about maintaining a sealed battery is to keep it fully charged. Since the battery is sealed and the sealing strip cannot be removed, you must use a voltmeter or multimeter to measure DC voltage.
For a refresh charge, follow all instructions carefully.
-
The battery should be disconnected from a load or charger for at least two hours before checking voltage. Check the battery voltage with a voltmeter or multimeter. A fully charged battery will register 12.6 V or higher.
-
If the voltage is less than 12.6 volts, recharge the battery at 1.2 amps or less until battery voltage is 12.6 or greater.
-
When using an automatic charger, refer to the charger manufacturer's instructions for recharging. When using a constant current charger, use the following guidelines via the table below.
Battery Charging (Sealed Battery)
Always verify battery condition before and 1-2 hours after the end of charging.
State of Charge |
Voltage |
Action |
Charge Time (Using constant current charger @ standard amps specified on top of battery) |
---|---|---|---|
100% |
12.6-12.8 volts |
Conventional/Low Maintenance Battery: check after 60 days AGM Battery: check after 30 days |
None required |
50%-75% |
12.0-12.5 volts |
Needs charge |
5-11 hours |
25%-50% |
11.5-12.0 volts |
Needs charge |
At least 13 hours, verify state of charge |
0%-25% |
11.5 volts or less |
AGM ONLY: needs charge with desulfating charger |
At least 20 hours |