DRY SHIPPED AGM BATTERIES
ACTIVATION
-
Do NOT activate the battery unless it will be put into regular service within 30 days. Only use the electrolyte container supplied with the battery to activate the battery.
-
Keep the electrolyte container in place for 20 minutes or longer until the container is completely empty. If necessary, gently tap the container to empty it.
-
Once the battery is fully charged, replace the strip of caps by hand. Do NOT use a tool to install the strip.
CHARGING
-
Polaris recommends using a BatteryMINDer® 2012 AGM - 2 AMP (PN 2830438) charger, which can be ordered through your normal parts channel.
-
Nominal voltage is 12.8 Volts when fully charged. If the voltage falls below 12.5V, charge it immediately, or the battery runs the risk of sulfation.
MAINTENANCE
-
Never add any electrolyte or distilled water to the battery once the battery is in service.
-
If you do not drive the vehicle for more than TWO weeks, maintain the battery with the BatteryMINDer® 2012 AGM - 2 AMP (PN 2830438) charger.
-
If you plan to store the vehicle for ONE month or longer, remove the battery from the vehicle and store the battery in a cool / dry location. Continue to maintain the battery with the BatteryMINDer® 2012 AGM - 2 AMP (PN 2830438) charger and inspect the battery every 60 days.
TESTING
-
If the test fails, fully charge the battery.
-
If the battery is too low to accept a charge, see the AGM Battery Charging - Deeply Discharged (Below 3 Volts) procedure in the Service Manual.
-
Proper load testing of the battery requires special equipment and can be performed by your dealer.