Charge Status Indicator
Troubleshooting Guide
      
      
      
      
      
      The code definitions provided are for informational purposes only. Please see your dealer for diagnosis and repair.
| # of Blinks | Code Definition | Solution | 
|---|---|---|
| 1 | Battery high voltage | Check battery size and condition; reset charger (interrupt AC power for 15 seconds) | 
| 2 | Battery low voltage | |
| 3 | Charge time-out, battery pack not reaching required voltage, charger output reduced due to high temperatures | Check connections; operate charger at lower ambient temperature | 
| 4 | Battery could not be trickle-charged to minimum voltage | Check battery for shorted or damaged cells | 
| 5 | Charger shut down due to overheating | Ensure sufficient cooling air flow (open the hood) and reset the charger (interrupt AC power for 15 seconds) | 
| 6 | Charger internal fault | Reset charger (interrupt AC power for 15 seconds); return to qualified service provider if fault persists |