Malfunction Indicator 
Troubleshooting Guide
      
      
      
      
      
      The malfunction codes will blink on the controller. The code definitions provided here are for informational purposes only.
 TIP
         
         If the indicator illuminates due to a minor issue
               such as a low voltage condition or a sequence fault (reversing direction
               without releasing the accelerator), select neutral and turn the key
               off and on to clear the error. If the error does not clear, please
               see your dealer for diagnosis and repair.
         | 
                        
                         # of Blinks  | 
                     
                     
                        
                         Code Definition  | 
                     
|---|---|
| 
                        
                         1  | 
                     
                     
                        
                         Data or configuration error  | 
                     
| 
                        
                         2  | 
                     
                     
                        
                         Sequence fault  | 
                     
| 
                        
                         3  | 
                     
                     
                        
                         Power fault  | 
                     
| 
                        
                         4  | 
                     
                     
                        
                         Contactor issue  | 
                     
| 
                        
                         6  | 
                     
                     
                        
                         Throttle input error  | 
                     
| 
                        
                         7  | 
                     
                     
                        
                         Voltage protection  | 
                     
| 
                        
                         8  | 
                     
                     
                        
                         Controller or motor out of temperature range  | 
                     
| 
                        
                         13  | 
                     
                     
                        
                         Software fault  |