Fluid Change
-
Elevate the vehicle using appropriate jack stands. Make sure the elevated vehicle is level.
-
Remove the fill plug 1.
-
Place a drain pan under the drain plug 2.

-
Remove the drain plug. Allow the fluid to drain completely.
-
Clean and reinstall the drain plug. Torque to specification.
TORQUE10-14 ft-lbs (14-19 Nm)NOTEUse a syringe to add the fluid. If a syringe is not available, remove the battery and use a funnel and tube to add the fluid. -
Add the recommended fluid. Do not overfill. Maintain the fluid level at the bottom edge of the fill hole.
CAPACITY23.7 oz (700 ml) -
Reinstall the fill plug. Torque to specification.
TORQUE10-14 ft-lbs (14-19 Nm) -
Check for leaks. Dispose of used fluid properly.