Battery Maintenance and Charging
Battery Storage
If storing your generator for an extended amount of time, Polaris recommends starting the generator once a month to charge the battery. Use the table below to determine how long the generator must run to fully charge the battery depending on the battery’s current state of charge. Always verify battery condition before and 1-2 hours after charge completion. Store the generator and battery in a cool, dry place.
State of Charge | Voltage (DC) | Action |
100% |
13 - 13.3 V |
No action; check monthly |
75%-100% |
12.7 - 13 V |
May need charge; if no charge given, check again in 2 weeks |
50%-75% |
12.3 - 12.7 V |
Needs charge |
25%-50% |
12 - 12.3 V |
Needs charge |
0%-25% |
12 V or less |
Needs charge |