Diagnostic Trouble Codes (DTCs) – Left Hand Controls
Matryx Left Hand Controls – Diagnostic Trouble Codes (DTCs) | |||||
---|---|---|---|---|---|
SPN = Suspect Parameter Number / FMI = Failure Mode Indicator | |||||
SPN | FMI | P-Code | Description | Fault Setting | Fault Healing |
516360 |
0 |
C1106 |
Left Grip Heater Driver Over Temp |
The temperature at left grip heater driver is greater than 60 DegC for 5 seconds |
The temperature at left grip heater driver is less than 60 DegC for 5 seconds |
5 |
C1107 |
Left Grip Heater Driver Under Current |
The current at left grip heater driver is is less than 1A for 5 seconds |
The current at left grip heater driver is is greater than 1.5A for 5 seconds |
|
6 |
C1108 |
Left Grip Heater Driver Over Current |
The current at left grip heater driver is is greater than 7A for 5 seconds |
The current at left grip heater driver is is less than 6A for 5 seconds |
|
31 |
C1109 |
Left Grip Heater Driver Internal Short |
An internal short has been detected at the left grip heater driver. This would result in a 100% duty cycle output when not expected. |
An internal short is not detected at the left grip heater driver. |
|
516361 |
0 |
C110A |
Right Grip Heater Driver Over Temp |
The temperature at right grip heater driver is greater than 60 DegC for 5 seconds |
The temperature at right grip heater driver is less than 60 DegC for 5 seconds |
5 |
C110B |
Right Grip Heater Driver Under Current |
The current at right grip heater driver is is less than 1A for 5 seconds |
The current at right grip heater driver is is greater than 1.5A for 5 seconds |
|
6 |
C110C |
Right Grip Heater Driver Over Current |
The current at right grip heater driver is is greater than 7A for 5 seconds |
The current at right grip heater driver is is less than 6A for 5 seconds |
|
31 |
C110D |
Right Grip Heater Driver Internal Short |
An internal short has been detected at the right grip heater driver. This would result in a 100% duty cycle output when not expected. |
An internal short is not detected at the right grip heater driver. |
|
516362 |
0 |
C110E |
Thumb Heater Driver Over Temp |
The temperature at thumb heater driver is greater than 60 DegC for 5 seconds |
The temperature at thumb heater driver is less than 60 DegC for 5 seconds |
5 |
C110F |
Thumb Heater Driver Under Current |
The current at thumb heater driver is is less than 0.2A for 5 seconds |
The current at thumb heater driver is is greater than 0.25A for 5 seconds |
|
6 |
C1110 |
Thumb Heater Driver Over Current |
The current at thumb heater driver is is greater than 1.4A for 5 seconds |
The current at thumb heater driver is is less than 1.2A for 5 seconds |
|
31 |
C1111 |
Thumb Heater Driver Internal Short |
An internal short has been detected at the thumb heater driver. This would result in a 100% duty cycle output when not expected. |
An internal short is not detected at the thumb heater driver. |